H30Crystal is a complete and versatile tool for present and future professional installers. It combines, in a single meter, the ability to analyze fibre optic networks, FTTx, Wifi networks, IPTV, and RF channels such as DVB-S/S2, DVB-T/T2, DVB-C (QAM Anex A/B), analogue and return channel. The equipment is scalable, which means that it is possible to incorporate new options and measurement standards through software licenses which are easily downloaded. Furthermore, the meter will always be up to date, since it incorporates automatic detection of software updates whenever the unit is connected to the internet.
In regards to simplicity and ease of using the meter, H30Crystal offers a revolutionary multiscreen function, that allows the user to remotely view and control the meter, from their own mobile device. Moreover, the H30Suite application allows you to manage it both in the field or the comfort of the office, export measurements, consult and edit channel plans and manage user profiles.
Controllable from any Android or iOS device or a PC with H30Suite
Accurate analysis for high-capacity networks
IPTV and RF services information
All bands (2.4 and 5 GHz)
IPTV and RF services information
Allows the demodulation and analysis of IPTV streams (both Unicast and Multicast), not only through video display but also by displaying the total bitrate and bitrate for each service. The relevant information for each service is already given: SID, VPID, AID, video profile, bit rate for both audio and video.
In addition, this option completes the RF measurements since all this information by service is analysed as well for this type of signals.
For IPTV signals, specific protocol measurements (UDP/RTP) are also analysed, such as UDP format, Media Loss Rate, Lost IP frames.
(*) Optional feature: Ref. 593251
From 5 MHz
The capacity of the meter to measure the backwards channel from 5 MHz is very useful for cable installation technicians. By displaying the signal in the spectrum, measuring power and C/N, it is possible to ensure a good status and quality of the upload data transmitted on this bandwidth.
Easy decision-making
Reduce installation mistakes with the on-screen Pass/Fail indicators, a graphical tool that helps and speeds up the interpretation of measurement results. Different thresholds are available depending on the network area to be analysed: headend, multi-band amplifiers, bridging connection, connection records, user home, etc. Besides the pre-set values, you will be able to customize your own threshold values.
All bands (2.4 and 5 GHz)
This functionality allows a full analysis of the Wi-Fi band for the automatic detection of all the networks. Each of them is identified by name, and the power of the signal at the access point is also displayed. Two display modes are provided for the user to choose. The “list” mode provides a list of the detected networks with the associated data and power, while the “map” mode represents them on a dual-axis map: power vs. frequency.
(*) Optional feature: Ref. 593250
Fully configurable equipment to meet your needs
H30Crystal is fully prepared to meet the specific needs of each individual user. It is a multi-standard equipment, ready to take measurements on the satellite band, but also on the terrestrial band channels. In order to meet the changing needs of individual users, the equipment allows them to easily add new options, with no need to send the meter back to the factory.
signal from any satellite
H30Crystal allows you to configure the parameters required for the reception of your satellite signal. To do this, H30Crystal allows pre-amplifier powering, and configuration of both DiSEqC and SCR parameters.
Optimize the learning curve
Scrolling through the menu is now very easy, thanks to its single-level structure, which includes all the functions in a very intuitive way: better utility, higher operation speed, and maximum productivity. No function requires more than three successive button pushes to achieve the desired operation. You will not find any easier-to-use device, and will be able to surf the different functions with no need for a user manual.
Access to the meter with H30Suite
Equipped with Wireless connectivity, the equipment allows secure access through an Android or iOS device, or a PC. The web management application H30Suite (ref. 100016) may be used to check and export stored measurements, access to quality profiles, meter settings cloning, meter registration through a friendlier interface or real-time consultation of the user manual.
H30Crystal is a complete and versatile tool for present and future professional installers.
H30Crystal | |
Mechanical Specifications | |
Screen | 2.8” TFT 400 x 240 full color |
Weight | 550 g. |
Dimensions | 175x100x52 mm / 6,9x3,9x2 (HxWxD) |
AC Adaptor | Input: 100-240V~ 50-60Hz Output: 12VDC, 3A |
Battery | Li-ion (7,2VDC, 2300mAh) |
Baterry range | >4hours without LNB powering |
Interfaces | Ethernet 1Gb USB 2.0 for Data log download and software upgrades |
Resilience | It withstands drops From 1 m (3.2 ft) onto concrete on all sides |
Storage capacity | 400 MB (internal) for measurements |
Impedance | F-type connector - 75 Ohm |
Technical Specifications | |||||||||||
593603 | 593601 | 593602 | 593604 | 593605 | 593621 | 593622 | 593624 | 593625 | 593661 | ||
Frecuency | |||||||||||
Range | Return path: 5-50 MHz / Terrestrial: 50 - 880 MHz / Satellite: 950 - 2400 MHz / Wideband: 250 - 2350 MHz | ||||||||||
Resolution | 125 kHz | ||||||||||
Tunning | Frequency or channel | ||||||||||
Spectrum analyser | |||||||||||
Span | 5, 10, 20, 50, 100, 200, 500 MHz and Full | ||||||||||
Scale | 5 and 10 dB/div | ||||||||||
Reference level (automatic and manual) | OK | ||||||||||
Optical fibre | |||||||||||
Not Selective | -40dBm to +7dBm | OK | OK | OK | OK | OK | - | - | - | - | OK |
Selective | -40dBm to +7dBm | - | - | - | - | - | OK | OK | OK | OK | - |
RF Overlay | -10dBm to +5dBm | OK | OK | OK | OK | OK | OK | OK | OK | OK | OK |
Optical Attenuation | OK | OK | OK | OK | OK | OK | OK | OK | OK | OK | |
DVB-S digital measurements [Modulation: QPSK] | |||||||||||
Image | OK | OK | OK | OK | OK | OK | OK | OK | OK | OK | |
Power | From 45 to 110 dBμV | OK | OK | OK | OK | OK | OK | OK | OK | OK | OK |
From 45 to 120 dBμV | Upgrade 593235** | Upgrade 593235** | Upgrade 593235** | Upgrade 593235** | Upgrade 593235** | Upgrade 593235** | Upgrade 593235** | Upgrade 593235** | Upgrade 593235** | Upgrade 593235** | |
CBER | 9.9E-2 – 1.0E-6 | OK | OK | OK | OK | OK | OK | OK | OK | OK | OK |
VBER | 1.0E-4 – 1.0E-8 | OK | OK | OK | OK | OK | OK | OK | OK | OK | OK |
MER | Up to 20dB | OK | OK | OK | OK | OK | OK | OK | OK | OK | OK |
C/N | Up to 20dB | OK | OK | OK | OK | OK | OK | OK | OK | OK | OK |
Constelation | OK | OK | OK | OK | OK | OK | OK | OK | OK | OK | |
DiSEqC | OK | ||||||||||
SCR | EN 50494 | OK | |||||||||
dCSS | EN 50607 | Upgrade 593234** | |||||||||
DVB-S2 digital measurements [Modulations: QPSK, 8PSK] | |||||||||||
Image | OK | OK | OK | OK | OK | OK | OK | OK | OK | OK | |
Power | From 45 to 110 dBμV | OK | OK | OK | OK | OK | OK | OK | OK | OK | OK |
From 45 to 120 dBμV | Upgrade 593235** | Upgrade 593235** | Upgrade 593235** | Upgrade 593235** | Upgrade 593235** | Upgrade 593235** | Upgrade 593235** | Upgrade 593235** | Upgrade 593235** | Upgrade 593235** | |
Link Margin | Up to 10 dB | OK | OK | OK | OK | OK | OK | OK | OK | OK | OK |
MER | Up to 20 dB | OK | OK | OK | OK | OK | OK | OK | OK | OK | OK |
LDPCBER* | 9.9E-2 – 1.0E-6 | OK | OK | OK | OK | OK | OK | OK | OK | OK | OK |
BCHBER* | 9.9E-2 – 1.0E-8 | OK | OK | OK | OK | OK | OK | OK | OK | OK | OK |
Constelation | OK | OK | OK | OK | OK | OK | OK | OK | OK | OK | |
DiSEqC | OK | ||||||||||
SCR | EN 50494 | OK | |||||||||
dCSS | EN 50607 | Upgrade 593234** | |||||||||
DVB-T digital measurements [Modulations: COFDM (QPSK, 16QAM, 64QAM)] | |||||||||||
Image | Upgrade 593231 | OK | OK | OK | OK | OK | OK | OK | OK | Upgrade 593231 | |
Power | From 45 to 110 dBμV | Upgrade 593231 | OK | OK | OK | OK | OK | OK | OK | OK | Upgrade 593231 |
From 45 to 120 dBμV | Upgrade 593231 + Upgrade 593235** | Upgrade 593235** | Upgrade 593235** | Upgrade 593235** | Upgrade 593235** | Upgrade 593235** | Upgrade 593235** | Upgrade 593235** | Upgrade 593235** | Upgrade 593231 + Upgrade 593235** | |
CBER | 9.9E-2 – 1.0E-6 | Upgrade 593231 | OK | OK | OK | OK | OK | OK | OK | OK | Upgrade 593231 |
VBER | 1.0E-3 – 1.0E-8 | OK | OK | OK | OK | OK | OK | OK | OK | ||
MER | Up to 35 dB | OK | OK | OK | OK | OK | OK | OK | OK | ||
C/N | Up to 40dB | OK | OK | OK | OK | OK | OK | OK | OK | ||
Echoes | OK | OK | OK | OK | OK | OK | OK | OK | |||
Constelation | OK | OK | OK | OK | OK | OK | OK | OK | |||
DVB-T2 digital measurements [Modulations: COFDM ( QPSK, 16QAM, 64QAM and 256 QAM)] | |||||||||||
Image | Upgrade 593231 + Upgrade 593232 | Upgrade 593232 | OK | OK | OK | Upgrade 593232 | OK | OK | OK | Upgrade 593232 | |
Power | From 45 to 110 dBμV | Upgrade 593231 + Upgrade 593232 | Upgrade 593232 | OK | OK | OK | Upgrade 593232 | OK | OK | OK | Upgrade 593232 |
From 45 to 120 dBμV | Upgrade 593231 + Upgrade 593232 + Upgrade 593235** | Upgrade 593232 + Upgrade 593235** | Upgrade 593235** | Upgrade 593235** | Upgrade 593235** | Upgrade 593232 + Upgrade 593235** | Upgrade 593235** | Upgrade 593235** | Upgrade 593235** | Upgrade 593232 + Upgrade 593235** | |
LDPCBER* | 9.9E-2 – 1.0E-6 | Upgrade 593231 + Upgrade 593232 | Upgrade 593232 | OK | OK | OK | Upgrade 593232 | OK | OK | OK | Upgrade 593232 |
BCHBER* | 1.0E-3 – 1.0E-8 | OK | OK | OK | OK | OK | OK | ||||
Link Margin | Up to 30 dB | OK | OK | OK | OK | OK | OK | ||||
MER | Up to 35 dB | OK | OK | OK | OK | OK | OK | ||||
C/N | Up to 40dB | OK | OK | OK | OK | OK | OK | ||||
Echoes | OK | OK | OK | OK | OK | OK | |||||
Constelation | OK | OK | OK | OK | OK | OK | |||||
DVB-C digital measurements [Modulations: 16QAM, 32QAM, 64QAM, 128QAM and 256 QAM] | |||||||||||
Image | OK | Upgrade 593233 | Upgrade 593233 | OK | OK | Upgrade 593233 | Upgrade 593233 | OK | OK | Upgrade 593233 | |
Power | From 45 to 110 dBμV | OK | Upgrade 593233 | Upgrade 593233 | OK | OK | Upgrade 593233 | Upgrade 593233 | OK | OK | Upgrade 593233 |
From 45 to120 dBμV | Upgrade 593235** | Upgrade 593233 + Upgrade 593235** | Upgrade 593233 + Upgrade 593235** | Upgrade 593235** | Upgrade 593235** | Upgrade 593233 + Upgrade 593235** | Upgrade 593233 + Upgrade 593235** | Upgrade 593235** | Upgrade 593235** | Upgrade 593233 + Upgrade 593235** | |
CBER | 1.E-2 – 1.0E-8 | OK | Upgrade 593233 | Upgrade 593233 | OK | OK | Upgrade 593233 | Upgrade 593233 | OK | OK | Upgrade 593233 |
MER | Up to 38 | OK | OK | OK | OK | OK | |||||
C/N | Up to 40dB | OK | OK | OK | OK | OK | |||||
Digital measurements ISBT-T/Tb | |||||||||||
Image | - | - | - | - | - | - | - | - | - | OK | |
Power | From 45 to 110 dBμV | - | - | - | - | - | - | - | - | - | OK |
From 25 to 120 dBμV | - | - | - | - | - | - | - | - | - | Upgrade 593235 | |
Pre-VER (by layer) | 9.9E-2 – 1.0E-6 | - | - | - | - | - | - | - | - | - | OK |
Post-VER (by layer) | 1.0E-3 – 1.0E-8 | - | - | - | - | - | - | - | - | - | OK |
MER | Up to 35 dB | - | - | - | - | - | - | - | - | - | OK |
C/N | Up to 40dB | - | - | - | - | - | - | - | - | - | OK |
Echoes | - | - | - | - | - | - | - | - | - | OK | |
Constelation | - | - | - | - | - | - | - | - | - | OK | |
Analogue measurements | |||||||||||
Level | 25 and 125 dBμV | OK | OK | OK | OK | OK | OK | OK | OK | OK | OK |
V/A | OK | OK | OK | OK | OK | OK | OK | OK | OK | OK | |
C/N | Up to 45dB | OK | OK | OK | OK | OK | OK | OK | OK | OK | OK |
Measurements and functions | |||||||||||
Wifi analyzer | Upgrade 593250 | Upgrade 593250 | Upgrade 593250 | Upgrade 593250 | OK | Upgrade 593250 | Upgrade 593250 | Upgrade 593250 | OK | Upgrade 593250 | |
IPTV analyser | Upgrade 593251 | Upgrade 593251 | Upgrade 593251 | Upgrade 593251 | OK | Upgrade 593251 | Upgrade 593251 | Upgrade 593251 | OK | Upgrade 593251 | |
Analog A/V display | Upgrade 593236 | Upgrade 593236 | Upgrade 593236 | Upgrade 593236 | Upgrade 593236 | Upgrade 593236 | Upgrade 593236 | Upgrade 593236 | Upgrade 593236 | Upgrade 593236 | |
4K - UHD display (HEVC) | OK | ||||||||||
Terrestrial plans | Channel plans from different regions of the world | ||||||||||
Satellite plans | Channel plans from different regions of the world | ||||||||||
Units | dBμV, dBmV, dBm | ||||||||||
Powering | 24 Vdc / 140 mA max. LNB: 13, 18 Vdc / 475, 370 mA max. |
||||||||||
LNB tono | 22 kHz |
* Notes:
LDPCBER is the BER measurement before LDPC correction.
BCHBER is the BER measurement after LDPC corrector and before BCH correction.
** Ref. 593234 & 593235: Free upgrade when registering the equipment
The H30 series consists of different customizable multistandard meters, all of them designed to carry out installation, maintenance and monitoring of telecommunications networks. Each model stands out for offering new functionalities, while preserving all the advantages of the previous model.
Through the following comparative table, it is possible to choose the most suitable meter model for each professional:
H30FLEX | H30EVOLUTION | H30CRYSTAL | ||
Multi-standard customizable | OK | OK | OK | |
Frequency range | Return P.: 5-50 MHz | X | X | OK |
Terrestrial: 50-880 MHz | OK | OK | OK | |
Satellite: 250-2400 MHz | OK (up to 2200MHz) | OK | OK | |
Screen | 2.8” TFT 400 x 240 full color | 2.8” TFT 400 x 240 full color | 2.8” TFT 400 x 240 full color | |
Multi-screen with touch control on mobile device | X | OK | OK | |
Smartphone armband | X | OK | OK | |
Wireless connectivity | X | OK | OK | |
WiFi analyzator | X | OK(*) | OK(*) | |
IPTV analyzator | X | OK(*) | OK(*) | |
Ethernet interface | OK | OK | OK | |
USB interface | USB (A-type) | USB (A-type) | USB (A-type) | |
Optical measures | X | X | OK | |
Guided satellite pointing | X | OK | OK | |
LNB Wideband compatible | X | OK | OK | |
4K - UHD displaying (HEVC) |
on the meter | X | X | OK |
on the mobile device | X | OK(*) | OK | |
Terrestrial input level to 120dBuV | OK(**) | OK(**) | OK(**) | |
dCSS compatible | OK(**) | OK(**) | OK(**) | |
Management interface access (datalogs, channel plan...) | Ethernet cable | Wireless / Ethernet cable | Wireless / Ethernet cable | |
Dimensions | 175x100x52 mm | 175x100x52 mm | 175x100x52 mm | |
Weight | 510 g. | 510 g. | 550 g. | |
Color | Black & White | Black & Grey | Light & dark grey |
* According to reference
** Free activation of the options with the meter registration